Spa Control System Error CodesThere are many brands and models of spa control systems on the market. The majority have used or do use either the same or similar error codes for a similar symptom. Rather than list error codes under equipment or spa brands, we have decided to list them alphabetically and numerically for ease of identification. In most cases you should either contact us for further diagnostics, or contact a local qualified spa service technician to resolve your problem quickly and accurately. The following codes cover brands such as: Gecko Electronics, Balboa Instruments, Hurricane, Sundance Spas, Hercules, Brett Aqualine, Splash Pool Accessories, Vita, Spaquip, Ampac, Onga, Dimension One, Sweetwater, and many more. There are many other error and operational codes not listed here - please contact us if you need further info or data, or if you error codes that we can add. Causes of the common following fault codes(most common fault) - Dirty filters (the most common cause), blockage, switch failure, low water level, pump failure, broken wire Flow/Pressure Switch Closed Circuit - Switch failure, switch adjustment required, debris in switch, splashed /leaking water shorting connectors Hi-Limit Fault - Dirty filters, low flow, low water level, blockage, sensor fault, water entry to sensor or connector Temperature Sensor Fault - Sensor fault, pump heat interference, water entry to sensor or connector/corrosion Over Heat Fault - Same as sensor fault - sensor reads extremely high temperature 45C-48C. Spa usually shuts down Error Code | Description | BJ2P | Hi-Limit - water temp too high | C4.4 | Hi- Limit | Cd, CLd | Freeze Condition | CE 01 | Stuck Touchpad button | CE 02 | No controller Data Communication | CE 03 | Temperature sensor fault | CE 04 | Water Sensor/Pressure switch fault | CE 05 | Over Temperature Condition | CE 06 | High Limit manual reset Klixon tripped | CE 07 | Stuck Relay | CE 08 | Temp Sensor Fault -( Spaquip Digital 2000 MK1 sensor) | CE 09 | Water Prime Fault - Lack of water | CoLd | spa heater temp below 40F | Cool, COOL, COL | Water is 11C below set point - not a fault | DR, dr, dy, DRY | Heater dry - insufficient water fault | Er0, Er1 | Temperature sensor faulty | Er2, Er3 | Hi-Limit fault | Er4 | Flow/Pressure switch short circuit | Error 3 - Spaquip | Stuck touchpad button | Error 4 | Water sensor fault | Error 5 | Over temperature | Error 6 | Klixon Tripped - over temp | Error 7 | Stuck Relay | Error 8 | Temperature sensor fault | Err | Software Program Fault | E### | pH probe out of calibration | E0 | Short circuit temperature sensor | E1 | Open circuit temperature sensor | E2 | short circuit/closed high limit sensor | E3 | Open circuit high limit sensor | E4 | Short circuit/closed pressure/flow switch | E7 | Improper electrical connection | FLO, Flo, FL1 | Flow/pressure switch open circuit - lack of flow or pressure or for Sundance/Spa Builders/Balboa - Flow switch is closed circuit | FLC, FL2 | Flow/pressure switch closed circuit - debris in switch, perforated diaphragm, faulty | FL | Pressure/flow switch failure | FLO (flashing) | Flow switch open circuit - Sundance/Spa Builders/ Balboa | FrE, Fr, FP | Freeze Condition | HiLi, HLEr | Water temperature above acceptable range | HL, HFL, HH, OHH | High limit sensor reading 45-48C, or above - check flow | Hold | Panel buttons pressed too many times too quickly | HOT | PCB thermistor above 82C | HP | Electronic controller error | H2O | Water Prime Fault - lack of water | ICE, IC | Freeze Condition | ILOC | Interlock failure, also caused by faulty ozonators, pumps and equipment | LEH | Temperature Sensor Fault | LF | Low Flow Fault | LO | Freeze Condition | LOC | Control Panel functions Locked | LS=0, LS=S | Multiple causes - open circuit sensor, faulty panel connection, improper voltage, etc | L1 | Panel Lock | L2 | Panel Lock | OH, OHS, oH | Overheat Condition 43-45C | OP | Open circuit sensor | P | Power overload – excess current draw | pd, Pd | Running on battery - power supply interrupted | PLUG | Sundance/Spa Builders Service Technician's Test Plug accidentally left connected to PCB | PnL, Pnl | Communication disrupted between touchpad and PCB | Pr | System Priming - not a fault | Prh | High limit sensor fault | Prr | Temperature sensor fault | PS | Flow/Pressure switch failure | PSoC, PSoL, PSoH | Pressure switch open circuit with Circulating, Low Speed, or High speed pumps | SA, SnA, SnH, Sb, Snb, Snt | Sensor Open Circuit or faulty - SnH - Hi Limit, SnT - Temp sensor | SEoP | Sensor Open Circuit | SESH | Sensor Short Circuit | SH | Short circuit sensor | Sn, SnS | Sensors out of balance | Sn1 | High Limit sensor fault | Sn2, Sn3 | Temperature sensor fault | SS=0, SS=S | Multiple causes - open circuit sensor, faulty panel connection, improper voltage, etc. | ToE | Time Out Error | 0.0 or 56 | Open/Closed circuit faulty temperature sensor | 000 | Programming Error | Or ** (2.5-9) | Over Range beyond permissible temperature – Programming Error | - 01 | Hi-Limit | - 02 | Temp sensor fault | - 03 | Flow/pressure switch open | - 04 | Flow/Pressure switch closed | - 07 | Hi-limit | 131 | Hi-limit | - - | Temperature unknown - displayed at power up for 2 minutes - not a fault | - - - - , - - - | Sundance/Spa Builders - 'Watchdog' - 48C reached, electronic fault, shuts system down. Major Fault | * * * (3 flashing dots under temp display) | Flow/Pressure switch either Open or Closed Circuit | * * * (as above, plus illuminated red LED on PCB) | High Limit Fault | Flashing Light Errors | Description | 3 flashing dots | Flow Error – FLO or FLC | 3 flashing dots and PCB | Same as OH | LED illuminated | | 1 flash - 3 second gap | High Limit fault | 2 flashes - 3 second gap | Pressure/Flow switch short circuit | 3 flashes - 3 second gap | Pressure/Flow switch open circuit | 4 flashes - 3 second gap | Open circuit Sensor(s) | Flash - 1 second on, 1 second off | Same as OH | Flash - briefly OFF once per second | Same as Sn1 or Sn3 | Flash - briefly ON once per second | Same as FLC | Blinking Power Indicator Light - Hydromate | High Limit tripped or, sensor fault | 1 flash per second - onga 4352, 53, 95, etc | Pressure switch open circuit - could also be motor, or motor thermal overload | 3 flashes per second - onga 4352, 53, 95, etc | Electronic fault – element sensor (most common cause) or PCB | Green flashes - Spaquip Pulsar/2095 series | Water sensor fault - lack of water | Red/Green alternate flashes | Temperature sensor fault, open circuit, or high limit tripped - push Reset Rod | Please note all Hot tub Parts sold are UK Spec, which means designed for 230 V at 50Hz |
|